General Application |
Current V4.4 Requirements |
V5.0 Draft Requirements |
Rationale |
Troffers |
100 lm/W |
105 lm/W |
≈5% efficacy increase |
Linear Ambient |
105 lm/W |
110 lm/W |
|
Outdoor-Low Output |
90 lm/W |
100 lm/W |
≈10% efficacy increase |
Outdoor-Mid Output |
95 lm/W |
105 lm/W |
|
Outdoor-High Output |
100 lm/W |
110 lm/W |
|
Outdoor-Very High Output |
100 lm/W |
110 lm/W |
|
Linear Replacement Lamps and 2G11 Lamps |
110 lm/W (bare lamp) |
120 lm/W (bare lamp) |
≈10% efficacy increase |
Four-Pin CFL Replacement Lamps |
75 lm/W (bare lamp) |
85 lm/W (bare lamp) |
|
Mogul Screw-Base (E39) Replacements for HID Lamps |
90-120 lm/W (In-luminaire) |
|
|
High Bay |
105 lm/W |
120 lm/W |
Considerable≈15% efficacy increase |
Case Lighting |
80 lm/W |
95 lm/W |
High≈20% efficacy increase. |
Interior Directional |
65 lm/W |
80 lm/W |
1) 颜色要求
Metric or/and Data Set |
Current V4.4 Requirements |
V5.0 Draft Requirements |
Method of Measurement/ Evaluation |
||
Standard |
Premium |
Tier 2 |
Tier 1 |
||
Chromaticity (CCT & Duv) |
依据ANSIC78.377-2015的7-step |
依据ANSIC78.377-2017的7-step享受DLC V4.4津贴 |
依据ANSIC78.377-2017的4-step 享受TBD津贴 |
IES LM-79-08 ANSI C78.377-2017 |
|
Consistency (of Chromaticity) |
N/A |
3个样品测试<0.006(CIE 1976) |
3个样品测试<0.003(CIE 1976) |
IES LM-79-08 ANSI C78.377-2017 |
|
Color Rendering* |
CRI (CIE 13.3-1995): Ra≥80 (indoor) Ra≥65 (outdoor) Ra≥70 (high bay) |
满足下列任一标准,并提供报告 ANSI/IES TM-30-18: IES Rf≥70 IES Rg≥89 -12%≤IES Rcs, h1≤+23% CIE 13.3-1995: Ra≥80 and R9≥0 |
满足下列任一标准,并提供报告 ANSI/IES TM-30-18: IES Rf≥78 IES Rg≥95 -1%≤IES Rcs, h1≤+15% CIE 13.3-1995: Ra≥90 and R9≥50 享受TBD津贴 |
IES LM-79-08 (ANSI/IES TM-30-18 Full Report and CIE 13.3-1995 complete Color Rendering Index Detail) |
|
Spectral Power Distribution |
N/A |
需报告380-780nm内每1nm的增量 |
IES TM-27-14, and/or ANSI/IES TM-33-18 |
||
Color Maintenance** |
N/A |
Δu'v'≤0.004 |
Δu'v'≤0.002 |
ANSI/IES LM-80-15, and/or IES LM-84-14 |
|
Angular Color Uniformity |
N/A |
可选,不强制要求 |
可选,不强制要求 |
IES LM-79-08 |
*:DLC V4.4 未对R9做任何要求,而V5.0明确要求R9≥0;
**:颜色维持率可依据LM-80来推断是否满足V 5.0要求
2) 健康方面
Metric and/or Data Set |
Current V4.4 Requirements |
V5.0 Draft Requirements |
Method of Evaluation |
Spectral Power Distribution |
N/A |
需报告380-780nm内每1nm的增量 |
IES TM-27-14, and/or ANSI/IES TM-33-18 |
Melanopic Flux* |
N/A |
需报告 |
As per CIE S 026/E:2018 |
M/P Ratio* |
N/A |
需报告 |
As per Lucas et al., 2014, and WELL v2, Appendix L1 |
Melanopic Daylight (D65) Efficacy Ratio * |
N/A |
需报告 |
As per CIE S 026/E:2018 |
*:虽然这些性能数据可以在报告上体现,但较终的影响取决于设计和现场条件。这个与人体视网膜感光和褪黑色素相关,待探讨
3) 光分布
A. 所有产品都需要有IES文件;
B. 除Flood and Spot Luminaires外,其余产品都需要报告BUG值。报告形式为B2 U0 G2;
C. Flood and Spot Luminaires and Interior Directional Luminaires须报告Beam Angle和Field angle值。
4) 眩光
Metric and/or Data Set |
Current V4.4 Requirements |
V5.0 Draft Requirements |
Method of Evaluation |
||
Threshold |
Reported |
Listing |
|||
.ies file |
.ies file for each optic variation |
None |
ies files for each variation |
N/A |
IES LM-79-08, ANSI/IES LM-63-02(R2008) and/or ANSI/IES TM-33-18 |
Unified Glare Rating (UGR) Applicable to indoor luminaires and indoor retrofit kits only |
No related requirement |
None |
Uncorrected UGR Table and Corrected UGR Table |
Designation of glare potential: Low * Medium High (to be defined in a later draft) |
Uncorrected UGR and corrected UGR tables generated using luminaire photometric data, per CIE 117-1995 and CIE 190-2010 |
Backlight, Uplight, and Glare (BUG) Applicable to outdoor luminaires and outdoor retrofit kits only |
No related requirement |
None |
BUG Rating |
G rating (BU listed as part of Distribution policy) |
BUG rating generated per IES TM-15-11 and Addendum A for IES TM-15-11 using luminaire photometric data |
*:低等级眩光产品享受TBD津贴。
5) 频闪
Metric |
Current V4.4 Require-ments |
V5.0 Draft Requirements |
Method of Evaluation |
||
Threshold |
Reported |
||||
Tier 1 |
Tier 2 |
||||
Short Term Flicker (Pst) |
n/a |
≤1.0 at ** and 20% light output |
Pst at **, 20%, and minimum fraction of light output |
ANSI/IES LM-xx-19 Approved Method: Measuring Optical Waveforms for use in Temporal Light Artifact (TLA) Calculations |
|
Stroboscopic Visibility Measure (SVM) |
n/a |
≤0.4 at ** and 20% light output |
≤0.9 at ** and 20% light output |
SVM at **, 20%, and minimum fraction of light output |
|
Percent Flicker |
n/a |
No required threshold |
Report values at **, 20%, and minimum fraction of light output for frequencies under 40, 90, 200, 400, and 1,000 Hertz |
||
Flicker Index |
n/a |
此次更新频闪要求借鉴了能源之星和JA10的技术要求。
Metric |
Current V4.4 Require-ments |
V5.0 Draft Requirements |
Method of Evaluation |
Dimming |
Reporting of dimming capability required for all products |
Dimming capability required for all products, with category exceptions. Continuous dimming required for indoor, stepped dimming for outdoor. |
Product documentation |
Integral Controls |
Reporting optional, with Yes/No answers of whether product has integral controls (Reporting required for Premium). |
Required to report, with additional information provided |
Product documentation |
Controls compatibility |
None |
Required to report method of inducing dimming in the product. |
Product documentation |
1) 调光
A. 调光被认为是灯具、改装套件和灯泡必须具备的功能;
B. 箱体照明、景观/泛光灯不受调光限制;
C. 室内灯具必须是连续调光,室外灯具可以是档位调光;
D. 可以通过改变功率和外部信号调整实现调光功能;
DLC V5.0预计会在2019年6月经过*2次讨论,并于9月发布正式版本,正式实施为2020年1月。
结合此次草案来看,未来发展方向为节能和健康,另新增了TBD津贴。2020预计有2大类产品会被下架。第一类:光效不满足V5.0技术要求的产品;第二类:R9<0的产品。所以,在接下来的一年时间里,各生产商需规避此2点技术要求。此外,此次草案借鉴了能源之星、加州能效、JA10等部分技术要求。